The Solution To The After-sale Trouble Of The Air Shower Room Oct 31, 2017

First, the power switch. Usually, there are four places in the air shower room to cut off power:

1. The power switch of the outdoor box of the wind shower;

2. The control Panel of the indoor box of the wind shower;

3, air shower on both sides of the outer box (where the power switch to prevent the emergency power off, effectively improve the staff's personal safety). When the power indicator does not pass, do not check the above four of the wind-shower room power supply.

1. The power switch of the outdoor box of the wind shower;

2. The control Panel of the indoor box of the wind shower;

3, air shower on both sides of the outer box (where the power switch to prevent the emergency power off, effectively improve the staff's personal safety). When the power indicator does not pass, do not check the above four of the wind-shower room power supply.

Second, the wind shower fan does not work. When the air shower does not work, the first time to check the air shower outside the emergency switch box is cut off, such as to determine the cut, with the hand gently press, to the right to rotate a little let go.

Third, wind shower fan reverse or wind shower room wind speed is very small, be sure to check the 380V three-phase four-wire line is reverse, general air shower manufacturer factory installed will have a special electrician to connect the line; If the source of the wind shower is reversed, the light will cause the fan to be not working or reverse the wind speed in the chamber, The heavy will burn the whole of the wind-room circuit board; It is recommended that the use of wind shower enterprises do not light to change the wiring, because the production needs to be determined to move, please consult with the wind room manufacturers to resolve.

Four, the wind shower room does not blow, in addition to the above three points, also need to check the air shower box inside the emergency stop button is pressed, such as the emergency stop button for the color, the wind shower room will not be blowing; to press the emergency stop button again to work properly.

Five, the wind shower room can not automatically induction blowing, please check the light sense system in the lower right corner of the indoor box, see if the light sense device is properly installed, if the light sense is opposite and the light sense is normal, then can automatically induce the shower.

Six, the wind shower use a period of time when the wind speed is very low, please check the air shower room at the beginning of the high efficiency filter is too much dust, if so please replace the filter. (The first effect of the air shower filter in general 1-6 months after the replacement, the air shower efficient filter in general 6-12 months replacement)


Previous: Precautions In The Air Shower Room

Next: No Information